Catalog Number: 1756sc-CTR8
Owners Guide 0300199-01 Rev. B
Vista de pagina 0
1 2 3 4 5 6 ... 73 74

Indice de contenidos

Pagina 1 - Catalog Number: 1756sc-CTR8

CONTROLLOGIX™COUNTER MODULECatalog Number: 1756sc-CTR8Owner’s Guide 0300199-01 Rev. B

Pagina 2

x ControlLogix™ Counter ModuleChapter 5Configuring moduleattributes:Configuration, Data,and Status Tags ...

Pagina 3 - Important Notes

Module OverviewThis chapter describes the counter module and explains how theControlLogix controller reads analog input data from the module. Readthi

Pagina 4

2 ControlLogix™ Counter ModuleInput TypesThe 1756-CTR supports both AC and DC input signal types. The moduleinput type is configured on a channel pai

Pagina 5

Chapter 1: Module Overview 3System OperationAt power-up, the module checks internal circuits, memory, and basicfunctions. During this time the SYS LE

Pagina 6 - Should Know

4 ControlLogix™ Counter Module

Pagina 7 - Preface vii

Installing And Wiring Your ModuleRead this chapter to install and wire your module. This chapter covers:• avoiding electrostatic damage• determining p

Pagina 8

Using your module in the ControlLogix SystemPlace your module in any slot of a ControlLogix modular, or modularexpansion chassis.An analog I/O module

Pagina 9 - Table of Contents

Removal and Insertion Under PowerThese modules are designed to be installed or removed while chassispower is applied.ATTENTION: When you insert or rem

Pagina 10

This equipment is classified as open equipment and must be installed(mounted) in an enclosure during operation as a means of providingsafety protectio

Pagina 11 - Chapter 1

2. Key the RTB in positions that correspond to unkeyed modulepositions. Insert the wedge-shaped tab on the RTB with the roundededge first. Push the ta

Pagina 13

• If the field wiring must cross ac or power cables, ensure that theycross at right angles.• To limit the pickup of electrical noise, keep signal wire

Pagina 14 - Counter Module

Important: If noise persists, try grounding the opposite end of the cable,instead (Ground one end only.)Wiring Single-endedInputsThe following figure

Pagina 15 - Requirements

Wiring Bi-Directional orQuadrature InputsInput use channel pairs, for example Hi2(A), Com, Hi2(B), Com. Thereis one gate input per channel pair.Hi 3

Pagina 17

Operation Within theControlLogix SystemThis chapter describes how the 1756sc-CTR8 analog module workswithin the ControlLogix system. This chapter cove

Pagina 18

Chapter 3: Operation within the System 151. Configure all I/O modules for a given controller using RSLogix 5000and download that inform

Pagina 19 - Wiring Your Module

16 ControlLogix™ Counter ModuleReal Time Sample (RTS)This configurable parameter instructs the module to perform thefollowing operations:1. scan a

Pagina 20

Chapter 3: Operation within the System 17The timing of this “reserved” spot may or may not coincide with theexact value of the RPI, but

Pagina 21 - Wiring Single-ended

18 ControlLogix™ Counter ModuleImportant: Only input modules can have multiple owners. If multipleowners are connected to the same input module, t

Pagina 22 - Quadrature Inputs

Chapter 3: Operation within the System 19

Pagina 23

Important Notes1. Please read all the information in this owner’s guide before installingthe product.2. The information in this owner's guide app

Pagina 24 - Chapter 3

Programming Your ModuleThis chapter explains how to program your module in the ControlLogixsystem. It also describes how the module’s input configura

Pagina 25

Chapter 4: Programming Your Module 21Step 1- Open the sample project with the CTR8 information. Openyour project. Drag and drop the CTR8 module into

Pagina 26 - Remote Chassis

22 ControlLogix™ Counter ModuleStep 2- Drag and drop the CTR8 user-defined data types from thesample project into your project.There are three CTR8 u

Pagina 27 - Input Modules

Chapter 4: Programming Your Module 23Step 3- Drag and drop the controller configuration tags from thesample project into your project.1. Right click

Pagina 28 - Multiple Owners

24 ControlLogix™ Counter ModuleStep 4- Create a new ladder logic routine in your project.1. In your project, right mouse click on the MainRoutine ite

Pagina 29

Chapter 4: Programming Your Module 25Configuring moduleattributes:Configuration TagsThe module has settings that are global and channel specific. The

Pagina 30 - Chapter 4

26 ControlLogix™ Counter ModuleData TagsThese tags represent the process data values in their final form.Status TagsThese tags report module status su

Pagina 31

Chapter 4: Programming Your Module 27

Pagina 32 - 22 ControlLogix

28 ControlLogix™ Counter ModuleConfiguration, Data,and Status TagsRead this chapter to:• send configuration data to the module• configure global modul

Pagina 33

Chapter 5: Channel Configuration, Data, and Status 29Configuration TagsThe following Global Module Settings and Channel Specific Settingssections allo

Pagina 35 - Configuration Tags

30 ControlLogix™ Counter ModuleUni-DirectionalWith this configuration, the input increments in an upward direction. All 8channels may be configured i

Pagina 36 - Status Tags

Chapter 5: Channel Configuration, Data, and Status 31BForward Rotation Reverse RotationAInput AInput BQuadratureEncoderBAx1 Countx4 Count1232101 2 3

Pagina 37

32 ControlLogix™ Counter ModuleStorageMode = 2 - Store/Wait/Resume StorageMode = 3 - Store-Reset/Wait/StartStorageMode = 4 - Store-Reset/StartInputRan

Pagina 38 - Chapter 5

Chapter 5: Channel Configuration, Data, and Status 33The M factor value expressed as a floating point number. This value ismultiplied by the counter

Pagina 39 - Settings

34 ControlLogix™ Counter ModuleOutput TagsDisable[x] 0,1 BOOLEnable the counter for channel [x].0=enable1=disableResetCounter[x] 0,1 BOOLResets counte

Pagina 40 - 30 ControlLogix

Chapter 5: Channel Configuration, Data, and Status 35StoredValue[x] 0-16777215 FLOATDisplays the value of the stored stored counts register. The maxi

Pagina 41

36 ControlLogix™ Counter ModuleCST DINTCoordinated System Time. This is the time that the processor reads datafrom the FPGA. It is not the actual ti

Pagina 42 - 32 ControlLogix

Chapter 5: Channel Configuration, Data, and Status 37

Pagina 43

38 ControlLogix™ Counter ModuleProgramming ExamplesEarlier chapters explained how the tag configuration defines the way themodule operates. This chap

Pagina 44 - Input Tags

Chapter 6: Ladder Program Examples 39Figure 5.1 Sample Ladder LogicRung 0 - This rung copies the configuration data (CTR8_Config) into themodule’s con

Pagina 45

PrefaceRead this preface to familiarize yourself with the rest of the owner’sguide. This preface covers:• who should use this guide• what this guide c

Pagina 46 - CST DINT

40 ControlLogix™ Counter ModuleYou may use either the SetAttributeAll to accomplish this.Set Attribute All message:

Pagina 47

Chapter 6: Ladder Program Examples 41Using the gatestorage modeThe gate storage mode allows you to configure the external gate to reactin several ways

Pagina 48 - Chapter 6

42 ControlLogix™ Counter ModuleStorageMode = 2 - Store/Wait/ResumeThis mode may be used in a situation were accumulated count isimportant but the proc

Pagina 49

Chapter 6: Ladder Program Examples 43InstallationRecommendationsHigh Impedance InputsIf the input device is an open collector type if may be necessary

Pagina 50 - Set Attribute All message:

44 ControlLogix™ Counter ModuleMeter ProvingThe 1756sc-CTR8 module provides a feature that allows the user toperform meter proving functions. A typic

Pagina 51 - Using the gate

Chapter 6: Ladder Program Examples 45

Pagina 52 - 42 ControlLogix

TroubleshootingUsing ModuleIndicators toTroubleshootThe count module has indicators which provide indication of modulestatus. ControlLogix modules use

Pagina 53 - Recommendations

Chapter 7: Testing Your Module 47The following LED display is used with ControlLogix analog inputmodules:Using RSLogix 5000to TroubleshootYour ModuleI

Pagina 54 - 1 2 3 4 NA

48 ControlLogix™ Counter ModuleFault information on the properties screen.Determining Fault TypeWhen you are monitoring a module’s properties dialog i

Pagina 55

Chapter 7: Testing Your Module 49Channel Specific ErrorsNote: n = channel number (0-7)0x010(n) Preset is defined larger than rollover limit for channe

Pagina 56 - Chapter 7

vi ControlLogix™ Counter Module1756 Series ControlLogix Module Installation Instructions(Each module has separate document for installation) 1756-5.5,

Pagina 57 - Your Module

50 ControlLogix™ Counter ModuleMaintaining Your ModuleAnd Ensuring SafetyRead this chapter to familiarize yourself with:• preventive maintenance• safe

Pagina 58 - Configuration Errors

Chapter 8: Maintaining Your Module And Ensuring Safety 51Standing Clear Of Machinery – When troubleshooting a problem withany ControlLogix system, hav

Pagina 59

52 ControlLogix™ Counter ModuleWARNINGEXPLOSION HAZARDWHEN IN HAZARDOUS LOCATIONS, TURN OFFPOWER BEFORE REPLACING OR WIRING MODULES.WARNINGTHIS DEVICE

Pagina 60 - Chapter 8

Chapter 8: Maintaining Your Module And Ensuring Safety 53

Pagina 61

Module SpecificationsThis appendix lists the specifications for the 1756sc-CTR8 CounterModule.ElectricalSpecificationsBackplane Current Consumption 23

Pagina 62

Appendix A: Module Specifications 55EnvironmentalSpecificationsOperating Temperature 0°C to 60°C (32°F to 140°F)Storage Temperature -40°C to 85°C (-40

Pagina 63

56 ControlLogix™ Counter ModuleAccuracyAccuracyAccuracyAccuracyAccuracyFrequency Mode 1Hz Accuracy 65kHz Accuracy max typ maxInstant* +/-0.00Hz +/-

Pagina 64 - Appendix A

Appendix A: Module Specifications 57

Pagina 65 - Input Specifications

Programming Your ModuleThis chapter explains how program your module in the ControlLogixsystem. It also describes how to the module’s input configura

Pagina 66 - Accuracy

Appendix B: Installing the module using a Generic Module profile 591. Open your project and go to the “Add I/O module” menu undercontroller configurat

Pagina 67

Preface viiDC - Direct Current - This is typically associated with a DC square-wave pulse signal from a flowmeter.dB (decibel) – A logarithmic measure

Pagina 68 - Appendix B

60 ControlLogix™ Counter ModuleOwner Controller Connection (Controller provides configuration)Listen-only controller connection. (Controller does not

Pagina 69

Appendix B: Installing the module using a Generic Module profile 614. Specify an RPI interval between 10.0 and 750.0 ms:

Pagina 70 - 60 ControlLogix

62 ControlLogix™ Counter Module

Pagina 71

Getting TechnicalAssistanceIf you need technical assistance, please review the information inChapter 6, “Testing Your Module,” before calling your loc

Pagina 72 - 62 ControlLogix

©2003 Spectrum Controls, Inc. All rights reserved. Specifications subject to change without notice.The Encompass logo and ControlLogix are trademarks

Pagina 73 - Conformity

viii ControlLogix™ Counter Module

Pagina 74

Table of Contents ixTable of ContentsPreface vWho Should Use This Guide ....................